Digital torque wrench angle

Digital torque wrench angle: Initially, install two AA batteries to power the unit. Subsequently, attach the 1/4-inch drive to measure 6-30 N-m. Moreover, monitor angles up to 360° with precise resolution. Furthermore, the device stores 50 memory records for tracking. Consequently, it shuts off after 80 seconds of inactivity. Finally, the three-color LED indicators provide immediate status feedback, ensuring professional accuracy during every use.

Manual Download Here

Feature:

  • Range: 6-30 N-m
  • Angle Range: 5° to 360°
  • Angle Display Resolution: 1°
  • Torque Display Resolution: 0.1
  • Memory: 50
  • Auto Shut Off: 80 Seconds
  • Battery: 2pcs AA

Size:

  • Square Drive:1/4"
Packaging:
  • 1pc/Blow Mould Case 

OPERATION MANUAL

How to use

Do not press "M" and " ⏻ " button together please.
The system will enter into Calibration Mode.
Turn off power please.

Battery Install and Replacement.

1. AAx2
2. Keep the end thread clean and dry for a good contact.
3. Open the battery cap.
4. Remove the old battery.
5. Install 2 pcs AA Battery in the housing. (with the "+" sign facing upwards).
6. Screw the battery cap.

Note
1. When battery are low LC.D will show "Lo".
2. Remove the battery if stored for a long period of time.
3. Notably, battery life depends on battery quality; additionally, the frequency of light and buzzer use significantly impacts duration.
4. Notably, typical battery life reaches up to 110 hours; however, actual performance varies based on usage intensity.

Power On.

1. Press and release the " ⏻ " button to turn the adaptor on.
    The LCD panel shows " br RCE"
2. After 2 seconds the L.C.D panel show " 0.0".
3. Swing the ratchet.
4. The L.C.D displays the torque value measured.

Note
If you do not use the ratchet for 150 seconds the digital angle adaptor will automatically shut off.

How to use Angle functions.

  1. Initially, place the adaptor on a flat surface; consequently, this ensures the device calibrates accurately from a stable base.
  2. Subsequently, press and release the "ANG/TOQ" button; consequently, the device will toggle between angle and torque modes.

3. The L.C.D will show "0000.0".

4. The L.C.D will show : 0°"

5. Swing the wrench.

6. Specifically, the LCD displays the measured angle value; for instance, counter-clockwise rotations show negative values while clockwise rotations show positive ones.

7. Stop use digital torque angle adaptor when the degree reach you need.

How to set Target Angle Value

1. Increase (+):
1-1: Press and hold the (+) button to increase the current target value.
1-2: The target value will show for 10 seconds.
1-3: After 10 seconds the L.C.D display " 0° "

2. Lower (-):
2-1: Press and hold the (-) button to increase the current target value.
2-2:The target value will show for 10 seconds.
2-3: After 10 seconds the L.C.D display " 0° "

How to select "Unit".

Press "M" and "P/T" button together and release to select different torque units.


Note
1. When you change units the target setting will also be changed to the new units value.
2. Specifically, this digital ratchet features three unit selections; namely, users can toggle between kg-m, ft-lb, and N-m.
3. Notably, the tool features a three-color LED light indicator; consequently, users can instantly monitor torque status through clear visual cues.

How to use Preset function

1. Press "M" bution, the L.C.D panel shows "PO1" than "O.O" or another reading

To increase (+):

  1. Subsequently, press and hold the (+) button; accordingly, the current target value will steadily increase.
  2. Subsequently, the LCD will display the reading; accordingly, users can easily monitor the real-time measurement.
  3. Subsequently, press and release the "M" button; accordingly, the system will save the current setting or enter the memory mode.
  4. Consequently, the pre-set value will be stored; thus, the device maintains your settings for future use.

To decrease (-):
1. Press and hold the (-) button to lower the current target value.
2. L.C.D will show the reading.
3. Press and released "M" button please.
4. The pre-set value will be stored.

If you need to pre-set another reading, follow the first step please.
There are 10 sets of reading that can be stored.

Note 3 color LED light indicator
1.Green light:
When you start to use digital torque angle adaptor the LED idicato will flash "green:..
2.Yellow light:
When you are approching 20% before the target, you will see a flash "yellow"and hear an
intermittent buzzer warring that the torgue is close.
3.Red light:
When the target values is attained the LED will change "red" light and an buzzer will sound.

How to set "Peak" or "Track".

Peak :
1. Press and release "P/T" - button when the digital adaptor is on.
2. The L.C.D panel shows " PtoP ".
3. The L.C.D panel shows 0.0 after 2 seconds.

Track :
1. Press and release "P/T" - button when the digital adaptor is on.
2. The L.C.D panel shows " br RCE ".
3. The L.C.D panel shows 0.0 after 2 seconds.

Turn Off.

1. If you do not use the adaptor for 150 seconds the digital adaptor will automatically shut off.
2. To manually turn off the digital adaptor press " ⏻ " button for 3 seconds then release.